Reversed phase raises a handful of sensible questions. This page answers them in order, starting with the fundamentals and moving to applications.
Reviewed 2026-06-17. Anything still debated is marked as such rather than presented as settled.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
The tumor-suppressor protein p53 accumulates when DNA is damaged due to a chain of biochemical factors. Part of this pathway includes alpha-interferon and beta-interferon, which induce transcription of the p53 gene, resulting in the increase of p53 protein level and enhancement of cancer cell-apoptosis. p53 prevents the cell from replicating by stopping the cell cycle at G1, or interphase, to give the cell time to repair; however, it will induce apoptosis if damage is extensive and repair efforts fail. Any disruption to the regulation of the p53 or interferon genes will result in impaired apoptosis and the possible formation of tumors.
The ASA is closely related to the concept of the solvent-excluded surface (also known as the Connolly's molecular surface area or simply Connolly surface), which is imagined as a cavity in bulk solvent. It is also calculated in practice via a rolling-ball algorithm developed by Frederic Richards and implemented three-dimensionally by Michael Connolly in 1983 and Tim Richmond in 1984. Connolly spent several more years perfecting the method. Implicit solvation Van der Waals surface VADAR tool for analyzing peptide and protein structures Relative accessible surface area
In an experiment described in the 2016 paper, rhesus macaques were infected with Ebola virus and treated with a combination of ansuvimab and another antibody isolated from the same subject, mAb100. Three doses of the combination were given once a day starting 1 day after the animals were infected. The control animal died and the treated animals all survived. In a second experiment described in the 2016 paper, rhesus macaques were infected with Ebola virus and only treated with ansuvimab. Three doses of ansuvimab were given once a day starting 1 day or 5 days after the animals were infected. The control animals died and the treated animals all survived. Unpublished data referred to in a publication of the 2018 Phase I clinical trial results of ansuvimab, reported that a single infusion of ansuvimab provided full protection of rhesus macaques and was the basis of the dosing used for human studies.
Korvezee was the youngest of two daughters of the pastor Willem Korvezee (1858–1913) and his wife Baukje Andringa (1874–1952). Her older sister, Elisabeth “Bets” Korvezee, later became the first female national archivist in the Netherlands. After their father's death in 1913, the family lived in The Hague, where both sisters attended the third municipal HBS, known as the “HBS-voor-jongens” (boys’ HBS), and Antonia showed particular talent for mathematics. She went on to study chemical technology at the Delft Institute of Technology, graduating cum laude in 1922. She then worked as an assistant, first in the department of analytical chemistry and from 1924 to 1938 in the laboratory of Scheffer. Under Frans Everhardus Cornelis Scheffer, she completed her doctorate cum laude in 1930 with a thesis titled “Copper chlorides as a catalyst for the Deacon process.” Between 1930 and 1932, she spent two six-month periods in Paris conducting research on radioactivity in Marie Curie’s laboratory. In 1935, her temporary appointment at Delft was made permanent, and she was appointed lecturer in radioactive decay. Korvezee was passed over for a professorship three times, first nominated in 1936 for the chair of analytical chemistry, and again in 1940 for the chair of physical chemistry despite ranking third in the nomination process.
Sources: en.wikipedia.org
The 5,10-methenyltetrahydromethanopterin hydrogenase (or Hmd), the so-called iron-sulfur cluster-free hydrogenase, is an enzyme found in methanogenic archea such as Methanothermobacter marburgensis. It was discovered and first characterized by the Thauer group at the Max Planck Institute in Marburg. Hydrogenases are enzymes that either reduce protons or oxidize molecular dihydrogen.
Work-related roadway crashes are the leading cause of death from traumatic injuries in the U.S. workplace. They accounted for nearly 12,000 deaths between 1992 and 2000. Deaths and injuries from these roadway crashes result in increased costs to employers and lost productivity in addition to their toll in human suffering. Truck drivers tend to endure higher fatality rates than workers in other occupations, but concerns about motor vehicle safety in the workplace are not limited to those surrounding the operation of large trucks. Workers outside the motor carrier industry routinely operate company-owned vehicles for deliveries, sales and repair calls, client visits, etc. In these instances, the employer providing the vehicle generally plays a major role in setting safety, maintenance, and training policy. As in non-occupational driving, young drivers are especially at risk. In the workplace, 45% of all fatal injuries to workers under age 18 between 1992 and 2000 in the United States resulted from transportation incidents.
AS9100 Revision C (2009), Quality Management System – Requirements for Aviation, Space and Defense Organizations The update of AS9100 from revision B to C is largely to address the following question: "Our supplier is repeatedly late on delivery and failing to meet our requirements, how is it possible that they still have their AS9100 certificate?" That is, the AS9100C changes are driven by repeated delivery of non-conforming product and repeated late delivery by organizations that held AS9100A/B certifications. Those organizations had documented controls that conformed to the standard, however, there were insufficient processes in place to assure effectiveness of those controls. The response in this AS9100 revision is to elevate the requirements for Risk Management and to make Risk Management an integrated theme throughout the standard. A major challenge to AS9100B-compliant organizations was the new AS9100 auditing standards defined in AS9101 Revision D, which eliminates the clause-based compliance checklist and requires organizations to provide evidence of effectiveness of their systems and processes. Summary of changes between AS9100B and AS9100C:
Clinical studies have repeatedly shown that even though insulin resistance is usually associated with obesity, the membrane phospholipids of the adipocytes of obese patients generally still show an increased degree of fatty acid unsaturation. This seems to point to an adaptive mechanism that allows the adipocyte to maintain its functionality, despite the increased storage demands associated with obesity and insulin resistance. A study conducted in 2013 found that, while INSIG1 and SREBF1 mRNA expression was decreased in the adipose tissue of obese mice and humans, the amount of active SREBF1 was increased in comparison with normal mice and non-obese patients. This downregulation of INSIG1 expression combined with the increase of mature SREBF1 was also correlated with the maintenance of SREBF1-target gene expression. Hence, it appears that, by downregulating INSIG1, there is a resetting of the INSIG1/SREBF1 loop, allowing for the maintenance of active SREBF1 levels. This seems to help compensate for the anti-lipogenic effects of insulin resistance and thus preserve adipocyte fat storage abilities and availability of appropriate levels of fatty acid unsaturation in face of the nutritional pressures of obesity.
5-Oxo-ETE contracts smooth muscle and organ-cultured bronchi isolated from guinea pigs but relaxes bronchi isolated from human lung; the relaxation of human bronchi caused by 5-oxo-ETE may not involve its OXER1. These results suggest that 5-oxo-ETE is not directly involved in the bronchoconstriction) that occurs in eosinophil-based allergic asthma reactions in humans. 5-Oxo-ETE (or other 5-HETE family member) stimulates the growth and/or survival of human cell lines derived from cancers of the prostate, breast, lung, ovary, colon and pancreas These preclinical studies suggest that 5-oxo-ETE (or other 5-HETE family member) may contribute to the cited cancers progression in humans. 5-oxo-ETE stimulates human H295R adrenocortical cells to increase transcription of steroidogenic acute regulatory protein messenger RNA and produce aldosterone and progesterone by an apparent OXER1-dependent pathway. 5-Oxo-ETE induces an isotonic volume reduction in guinea pig intestinal crypt epithelial cells.
Sources: en.wikipedia.org
In March 2008, AFRL's Human Effectiveness Directorate located at Wright-Patterson AFB was merged with the Air Force School of Aerospace Medicine and the Human Performance Integration Directorate from the 311th Human Systems Wing both located at Brooks City-Base, Texas to form the 711th Human Performance Wing. In its vision statement, the wing includes the goals of improving aerospace medicine, science and technology, and human systems integration. The current Commander of the 711th is Brig. Gen. Timothy Jex. One practical application of its work is ensuring and advancing the safety of ejection systems for pilots. With the increasing number of females in the Air Force ranks, anthropometry is of greater import now than ever, and 711th's WB4 'whole-body scanner' enables swift and accurate acquisition of anthropometric data which may be used to design pilot equipment with a better fit for comfort and safety.
Dysphoria and apathy (due to dopamine receptor blockade) Sedation (particularly common with asenapine, clozapine, olanzapine, quetiapine, chlorpromazine and zotepine) Headaches Dizziness Diarrhea Anxiety Extrapyramidal side effects (particularly common with first-generation antipsychotics), which include: Akathisia, an often distressing sense of inner restlessness. Dystonia, an abnormal muscle contraction Pseudoparkinsonism, symptoms that are similar to what people with Parkinson's disease experience, including tremulousness and drooling Hyperprolactinaemia (rare for those treated with clozapine, quetiapine and aripiprazole), which can cause: Galactorrhoea, the unusual secretion of breast milk. Gynaecomastia, abnormal growth of breast tissue Sexual dysfunction (in both sexes) Osteoporosis Orthostatic hypotension Weight gain (particularly prominent with clozapine, olanzapine, quetiapine and zotepine, can be counteracted by starting the drug with metformin) Antipsychotic medication-induced weight gain (AIWG) is a difficult-to-manage condition. In a meta-analysis analyzing data from 9 studies having more than 40,000 patients with AIWG, use of semaglutide was on an average was associated with 7.37kg weight loss with a good reduction in waist circumference. The occurrence of psychiatric adverse events was lower in semaglutide users.
March 12 – 17: 2018 Youth Pan American Championships (Men) in Guadalajara In the final, Argentina defeated Mexico, 3–2. Canada took third place and Paraguay took fourth place. March 12 – 17: 2018 Youth Pan American Championships (Women) in Guadalajara In the final, Argentina defeated Uruguay, 4–0. Mexico took third place and Paraguay took fourth place. May 13 – 20: 2018 Asian Women's Hockey Champions Trophy in Donghae City South Korea defeated India, 1–0, to win their third Asian Women's Hockey Champions Trophy title. China took third place. October 18 – 28: 2018 Asian Men's Hockey Champions Trophy in Muscat Note: Due to heavy rain, both India and Pakistan took first place here. Malaysia took third place. July 11 – 15: IFA 2018 Fistball U18 World Championships in Roxbury Township July 24 – 28: IFA 2018 Fistball Women's World Championship in Linz
The area under the effect curve (AUEC) is an integral of the effect of a drug over time, estimated as a previously-established function of concentration. It was proposed to be used instead of AUC in animal-to-human dose translation, as computer simulation shows that it could cope better with half-life and dosing schedule variations than AUC. This is an example of a PK/PD model, which combines pharmacokinetics and pharmacodynamics. Cmax (pharmacology) Cmean (pharmacology) "Area Under Curve" of the Receiver operating characteristic
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
It is a set of checks performed before or during an HPLC run to confirm the system works as expected. Parameters may include resolution, tailing factor, theoretical plates, and retention time precision. Failure can trigger maintenance, method adjustment, or repeat analysis.