Quality control comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Last reviewed on 2025-09-21. Where a claim depends on a specific study, the study is described rather than over-claimed.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
Because lipopolysaccharides are potent inflammatory agents, and the action of antibiotics can result in the release of these compounds, the binding capacity of BPI was explored as a possible means of reducing injury. Xoma Ltd. developed a recombinant 21kDa portion of the BPI molecule called rBPI21, NEUPREX, or opebecan. In a trial, it was found to decrease the mortality of Gram-negative bacterial-induced sepsis. Studies suggest that its binding activity is not the means by which it mediates its protective effect. Studies show biological effects with Gram-positive bacteria and even in infection by the protozoan, Toxoplasma gondii. The N-terminal portion of murine BPI (199 amino acids) genetically fused to Halobacterium sp. NRC-1 GvpC protein was bound to the surface of gas vesicle nanoparticles (GVNPs) and tested for protective activity using a murine model of endotoxic shock. Depending on the time of delivery and exposure to lethal concentrations of lipopolysaccharide (LPS) and D-galactosamine, the treatment resulted in increased survival and reduced symptoms of inflammation, including inflammatory anemia, recruitment of neutrophils, liver apoptosis as well as increased pro-inflammatory serum cytokine levels. When administered via footpad and before LPS exposure, there was 100% survival of the experimental cohort.
Seven genes encode seven distinct 14-3-3 proteins in most mammals (See Human genes below) and 13–15 genes in many higher plants, though typically in fungi they are present only in pairs. Protists have at least one. Eukaryotes can tolerate the loss of a single 14-3-3 gene if multiple genes are expressed, but deletion of all 14-3-3s (as experimentally determined in yeast) results in death. 14-3-3 proteins are structurally similar to the Tetratrico Peptide Repeat (TPR) superfamily, which generally have 9 or 10 alpha helices, and usually form homo- and/or hetero-dimer interactions along their amino-termini helices. These proteins contain a number of known common modification domains, including regions for divalent cation interaction, phosphorylation & acetylation, and proteolytic cleavage, among others established and predicted. 14-3-3 binds to peptides. There are common recognition motifs for 14-3-3 proteins that contain a phosphorylated serine or threonine residue, although binding to non-phosphorylated ligands has also been reported. This interaction occurs along a so-called binding groove or cleft that is amphipathic in nature. To date, the crystal structures of six classes of these proteins have been resolved and deposited in the public domain.
Apitegromab, sold under the brand name Isembyld, is a fully human IgG4 lambda monoclonal antibody used for the treatment of spinal muscular atrophy. It is a recombinant monoclonal antibody targeting proforms of myostatin. The most common side effects include upper respiratory tract infections, vomiting, cough, other viral infections, headache, gastroenteritis, and pharyngitis (sore throat). Apitegromab was approved for to treat Spinal Muscular Atrophy in the United States in September 2026. Apitegromab is indicated for the treatment of spinal muscular atrophy in people aged two years of age and older who are currently receiving a survival motor neuron 2-targeted treatment.Spinal muscular atrophy is a rare, progressive neuromuscular disease affecting approximately 1 in 10,000 live births and is among the leading genetic causes of infant mortality. It is caused by a faulty survival motor neuron 1 (SMN1) gene that fails to produce a protein essential for motor neuron survival, leading to progressive muscle weakness and wasting.
The linear amino acid sequence of a protein is called the primary structure. The primary structure can be easily determined from the sequence of codons on the DNA gene that codes for it. In most proteins, the primary structure uniquely determines the 3-dimensional structure of a protein in its native environment. An exception is the misfolded prion protein involved in bovine spongiform encephalopathy. This structure is linked to the function of the protein. Additional structural information includes the secondary, tertiary and quaternary structure. A viable general solution to the prediction of the function of a protein remains an open problem. Most efforts have so far been directed towards heuristics that work most of the time.
Camurus is a company focused on the development of lipid lyotropic liquid crystal structures for pharmaceutical drug delivery applications. These structures are well-defined three-dimensional formations consisting of lipophilic and hydrophilic domains that can be either interconnected or isolated depending on the environmentally induced phase conditions. The unique crystalline structures offer a unique way of encapsulating and transporting Active pharmaceutical ingredients, such as small molecules, peptides and proteins through the body. The structures also allow for the use of controlled release and prevention of degradation of fragile short half live molecules, a serious issue for amino-acid based drugs.
Sources: en.wikipedia.org
Nanoghosts are nanosized vesicles containing a chosen drug delivery payload manufactured from extracted leukocyte membranes with the cell cytoplasm content removed. The use of biological membranes serves to mask the particles from the immune system to reduce the likelihood of an immunogenic response, as well as to extend circulation of the particles in the blood. They are produced by homogenizing the cells to remove the cytosol, and then sonicating the empty cell membranes to create nanoghosts between 100 and 200 nm in diameter. Membranes used to make nanoghosts harvested form red blood cells have been shown to circulate for about 120 days and avoid phagocytotic cells. Neutrophil based nanoghosts retain the chemotaxis capacity of neutrophils to sites of inflammation, which encourages tumor targeting. NK based nanoghosts exhibit metastatic cancer targeting behavior. Monocyte based nanoghosts are effective at infiltrating the tumor microenvironment. Mesenchymal stem cell derived nanoghosts exhibit cancer targeting properties.
As with bacterial classification, identification of bacteria is increasingly using molecular methods, and mass spectroscopy. Most bacteria have not been characterised and there are many species that cannot be grown in the laboratory. Diagnostics using DNA-based tools, such as polymerase chain reaction, are increasingly popular due to their specificity and speed, compared to culture-based methods. These methods also allow the detection and identification of "viable but nonculturable" cells that are metabolically active but non-dividing. The main way to characterize and classify these bacteria is to isolate their DNA from environmental samples and mass-sequence them. This approach has identified thousands, if not millions of candidate species. Based on some estimates, more than 43,000 species of bacteria have been described, but attempts to estimate the true number of bacterial diversity have ranged from 107 to 109 total species—and even these diverse estimates may be off by many orders of magnitude.
In Brazil, the Aeronautical Accidents Investigation and Prevention Center (CENIPA) was established under the auspices of the Aeronautical Accident Investigation and Prevention Center, a Military Organization of the Brazilian Air Force (FAB). The organization is responsible for the activities of aircraft accident prevention, and investigation of civil and military aviation occurrences. Formed in 1971, and in accordance with international standards, CENIPA represented a new philosophy: investigations are conducted with the sole purpose of promoting the "prevention of aeronautical accidents". In Canada, the Transportation Safety Board of Canada (TSB), is an independent agency responsible for the advancement of transportation safety through the investigation and reporting of accident and incident occurrences in all prevalent Canadian modes of transportation – marine, air, rail and pipeline. In China, the Civil Aviation Administration of China (CAAC) is solely responsible for all air investigations and safety inside the country after the split from the formal CAAC Airlines.
Galega officinalis (French lilac) was used in diabetes treatment for centuries. In the 1920s, guanidine compounds were discovered in Galega extracts. Animal studies showed that these compounds lowered blood glucose levels. Some less toxic derivatives, synthalin A and synthalin B, were used for diabetes treatment, but after the discovery of insulin, their use declined. Biguanides were reintroduced into Type 2 diabetes treatment in the late 1950s. Initially phenformin was widely used, but its potential for sometimes fatal lactic acidosis resulted in its withdrawal from most pharmacopeias (in the U.S. in 1978). Metformin has a much better safety profile, and it is the principal biguanide drug used in pharmacotherapy worldwide.
Sources: en.wikipedia.org
From 1935–1972, the authorising body governing radiation in Australia was the Commonwealth X-Ray and Radium Laboratory. This was replaced by the Commonwealth Radiation Laboratory (1972–1973), and then the Australian Radiation Laboratory (1973–1999). In 1999, the Australian Radiation Laboratory then merged with the Nuclear Safety Bureau to create one agency that governed radiation and nuclear safety, ARPANSA. Since its establishment, ARPANSA has offices in both Sydney, NSW, and Melbourne, Victoria.
In collaboration with the Academic Medical Center in Amsterdam, Inreda Diabetic B.V. has developed a closed loop system with insulin and glucagon. The initiator, Robin Koops, started to develop the device in 2004 and ran the first tests on himself. In October 2016 Inreda Diabetic B.V. got the ISO 13485 license, a first requirement to produce its artificial pancreas. The product itself is called Inreda AP, and soon made some highly successful trials. After clinical trials, it received the CE marking, noting that it complies with European regulation, in February 2020. In October 2020 the health insurance company Menzis and Inreda Diabetic then started a pilot with 100 patients insured by Menzis. These are all patients that face very serious trouble in regulating their blood glucose levels. They now use the Inreda AP instead of the traditional treatment. Another large scale trial with the Inreda AP was set up in July 2021, and should determine whether Dutch health insurance should cover the device for all their insured. A smaller improved version of the Inreda AP is scheduled for release in 2023.
As mentioned above, G-proteins may terminate their own activation due to their intrinsic GTP→GDP hydrolysis capability. However, this reaction proceeds at a slow rate (≈0.02 times/sec) and, thus, it would take around 50 seconds for any single G-protein to deactivate if other factors did not come into play. Indeed, there are around 30 isoforms of RGS proteins that, when bound to Gα through their GAP domain, accelerate the hydrolysis rate to ≈30 times/sec. This 1500-fold increase in rate allows for the cell to respond to external signals with high speed, as well as spatial resolution due to limited amount of second messenger that can be generated and limited distance a G-protein can diffuse in 0.03 seconds. For the most part, the RGS proteins are promiscuous in their ability to deactivate G-proteins, while which RGS is involved in a given signaling pathway seems more determined by the tissue and GPCR involved than anything else. In addition, RGS proteins have the additional function of increasing the rate of GTP-GDP exchange at GPCRs, (i.e., as a sort of co-GEF) further contributing to the time resolution of GPCR signaling. In addition, the GPCR may be desensitized itself. This can occur as:
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.